{"title":"HEPA Filter Testing","description":"\u003cheader\u003e\u003c\/header\u003e\n\u003cp class=\"text-justify\"\u003eAerosol photometers and generators are the critical instruments in ensuring cleanroom and HVAC compliance. Generators create a controlled cloud of airborne particles or liquid droplets of a specific, uniform size, while photometers detect them to spot invisible HEPA\/ULPA filter leaks. Together, they protect sterile manufacturing and laboratory environments from costly contamination. Filter integrity testing is required once or twice a year, depending on the ISO class of the cleanroom. The use of portable photometers and aerosol generators are the industry standard for HEPA Filter testing.\u003c\/p\u003e\n\u003cp class=\"text-justify\"\u003e\u003cstrong\u003eCommon Applications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"text-justify\"\u003eCleanroom Validation: Ensures that manufacturing environments in pharmaceuticals, semiconductor fabrication, and aerospace remain completely free of contaminants.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"text-justify\"\u003eBiosafety Cabinets (BSCs): Certifies that laboratory hoods adequately protect operators from hazardous pathogens. \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"text-justify\"\u003eHospital Environments: Confirms that isolation rooms and surgical suites meet strict air quality and containment standards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","products":[{"product_id":"photometer","title":"Photometer RI7001","description":"\u003cp\u003e\u003cspan\u003eThe Rigel RI7001 digital photometer is the best choice for testing the integrity of HEPA filters. Using the light scattering method, the Rigel RI7001 provides real-time integrity through detection of aerosol concentration upstream and downstream. The 3.5″ LCD on the base unit provides an easy to read interface displaying sample concentration in real time and frequency modes. The scanning probe attachment not only focuses the capture of the sample but adds value by incorporating a 2.8″ LCD screen, eliminating the need to look back at the main unit by placing pertinent sample data conveniently within the operator’s “line of sight” and the scanning probes point of application. Moreover, the included thermal printer gives you the opportunity to report your samples in order to complete your tests or validation documents. The Rigel RI7001 tests, monitors and validates clean rooms, laminar flow hoods, safety cabinets, glove boxes, HEPA vacuum cleaners, HVAC systems, HEPA filters, ULPA filters, filtration units, negative pressure operating rooms, nuclear filter banks, collective protection filters.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable class=\"contenttable\" style=\"width: 100%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 52.2892%;\"\u003eType of device\u003c\/td\u003e\n\u003ctd style=\"width: 47.3498%;\"\u003eForward Light Scattering Photometer for aerosol concentration measuring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 52.2892%;\"\u003eField of use\u003c\/td\u003e\n\u003ctd style=\"width: 47.3498%;\"\u003eHEPA\/ULPA filter integrity\/seal tests (ISO 14644-3 )\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 52.2892%;\"\u003eMeasurement type\u003c\/td\u003e\n\u003ctd style=\"width: 47.3498%;\"\u003eConcentration measurement:\u003cbr\u003e-percentage from 0.0001% a 100.0% with respect to a reference value (5-100 µg\/litre)\u003cbr\u003e-absolute with respect to a reference equal to 100 µg\/litre\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 52.2892%;\"\u003eAlarm threshold\u003c\/td\u003e\n\u003ctd style=\"width: 47.3498%;\"\u003eVisual and\/or audio alarm which can be selected by the user; active when set threshold is exceeded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 52.2892%;\"\u003eOutput\u003c\/td\u003e\n\u003ctd style=\"width: 47.3498%;\"\u003eRS232 connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 52.2892%;\"\u003eReporting\u003c\/td\u003e\n\u003ctd style=\"width: 47.3498%;\"\u003e-on internal memory (Save only mode)\u003cbr\u003e-on printer (Print only mode)\u003cbr\u003e-on printer and internal memory (Print\u0026amp;Save mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 52.2892%;\"\u003eScanning Probe\u003c\/td\u003e\n\u003ctd style=\"width: 47.3498%;\"\u003e2.8” LCD Display, 2.5 m connection cable with Photometer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 52.2892%;\"\u003eLight Source\u003c\/td\u003e\n\u003ctd style=\"width: 47.3498%;\"\u003eService life \u0026gt; 50,000 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 52.2892%;\"\u003eElectrical supply\u003c\/td\u003e\n\u003ctd style=\"width: 47.3498%;\"\u003e230 V (+-10%) 50-60 Hz single-phase 1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 52.2892%;\"\u003eElectrical protection\u003c\/td\u003e\n\u003ctd style=\"width: 47.3498%;\"\u003e2 fuses 5×20 mm 250V F 2A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 52.2892%;\"\u003eAmbient conditions during operation\u003c\/td\u003e\n\u003ctd style=\"width: 47.3498%;\"\u003eTemperature from +1°C to + 40°C Relative humidity \u0026lt; 95% not condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 52.2892%;\"\u003eAmbient storage conditions\u003c\/td\u003e\n\u003ctd style=\"width: 47.3498%;\"\u003eTemperature from – 20°C to + 55°C Relative humidity \u0026lt; 95% not condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 52.2892%;\"\u003eDimensions (L x D x H)\u003c\/td\u003e\n\u003ctd style=\"width: 47.3498%;\"\u003e260x370x160 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 52.2892%;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"width: 47.3498%;\"\u003e10 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"PMT (GB) Ltd.","offers":[{"title":"Default Title","offer_id":43435895717977,"sku":null,"price":0.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1673\/4797\/files\/R17001_1vsmall.jpg?v=1781519132"},{"product_id":"photometer-ri7001-copy","title":"Photometer RI7002","description":"\u003cp\u003eThe RI7002 Photometer is used in testing the integrity, checking leakages and breakages in high efficiency filter systems (HEPA \u0026amp; ULPA). Using the light scattering method, the Rigel RI7002 provides real-time integrity through detection of aerosol concentration upstream and downstream.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eSettable audible and visual alarms signal when user-defined set-points are exceeded\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eVacuum pump for ensuring a constant flow of sampled air of 1 CFM (28.3 litres\/min)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eA system of solenoid valves allows the flow to be selected between three different sources: through an absolute filter for detecting the reference zero (CLEAR), from a position entering the filter being tested (UPSTREAM), from a position downstream of the filter being tested (DOWNSTREAM)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eElectro-optical scattering chamber\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLuminous source for radiation of the particles inside the scattering chamber\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOptical system for collecting the light diffused by the particles on a photomultiplier tube\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eElectronic system consisting of linear amplifier of the signal coming from the photomultiplier\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMicroprocessor\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTouch screen display\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePower supply unit\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"PMT (GB) Ltd.","offers":[{"title":"Default Title","offer_id":43435926028377,"sku":null,"price":0.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1673\/4797\/files\/Fotometrocompletofrontale.png?v=1781521531"},{"product_id":"photometer-ri7002-copy","title":"Aerosol Generator RI8201","description":"\u003cp\u003e\u003cspan\u003eThe Rigel RI8201 Aerosol Generator is designed to be an “All-in-one” instrument. The built-in compressor gives the opportunity to work with the aerosol generator even if there is any external compressor available. Using Laskin nozzles placed within the tank of the instrument, the aerosol is vaporized. It is ideal for the certification of small and medium-sized areas, when low range of airborne concentration are required. The Rigel RI8201 includes rugged stainless-steel construction, large fill port, individual nozzle control, and a 3″ standard sanitary fitting outlet. An 3” hose adapter (included within the unit) is available for introducing the aerosol into positive pressure systems. RI8201 gives its best in RABS, isolators and safety cabinets.\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable class=\"contenttable\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eType of device\u003c\/td\u003e\n\u003ctd\u003eAerosol generator of cold atomized oil produced by Laskin nozzles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField of use\u003c\/td\u003e\n\u003ctd\u003eHigh efficiency filtering systems integrity tests (ISO 14644-3 – Section 3.2.1) in the flow range 50 ÷ 2000 cfm ( 85 ÷3398 m3\/h )\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAerosol type\u003c\/td\u003e\n\u003ctd\u003ePolidispersed (cold)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAtomizers\u003c\/td\u003e\n\u003ctd\u003e2 \/ 6 Laskin nozzles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAerosol Concentration\u003c\/td\u003e\n\u003ctd\u003eManual regulation: 100μg\/l @ 200 cfm 10μg\/l @ 2000 cfm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible oil type (*)\u003c\/td\u003e\n\u003ctd\u003eIn accordance with the types indicated in ISO 14644-3 (Section C.6.4): DOP (Dioctyl Phthalate) – PAO (Polyalphaolefin) – DOS (Dioctyl sebacate) – DEHS (di-2-ethylhexyl sebacate) – Shell Ondina EL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOil tank capacity\u003c\/td\u003e\n\u003ctd\u003e2 Litres\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOil level\u003c\/td\u003e\n\u003ctd\u003eCheck window\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower supply\u003c\/td\u003e\n\u003ctd\u003e230 V 50-60 Hz 3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical protection\u003c\/td\u003e\n\u003ctd\u003e2 fuses 5×20 mm 250V F10A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eService compressed air\u003c\/td\u003e\n\u003ctd\u003ePressure Max 3 bar (limited by safety valve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental conditions during operation\u003c\/td\u003e\n\u003ctd\u003eTemperature 0 °C ÷ + 40 °C Relative Humidity 10 ÷ 90%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage environmental conditions\u003c\/td\u003e\n\u003ctd\u003eTemperature – 20 °C ÷ + 55 °C Relative Humidity 10 ÷ 90% non condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCase\u003c\/td\u003e\n\u003ctd\u003eAluminum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (L x P x H)\u003c\/td\u003e\n\u003ctd\u003e390 x 260 x 290 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e16.8 kg (dry)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"PMT (GB) Ltd.","offers":[{"title":"Default Title","offer_id":43435929337945,"sku":null,"price":0.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1673\/4797\/files\/RI8201_2small.jpg?v=1781522476"},{"product_id":"aerosol-generator-ri8201-copy","title":"Aerosol Generator RI8303","description":"\u003cp\u003e\u003cspan\u003eThe Rigel RI8303 Aerosol Generator is designed to be portable and versatile. Using Laskin nozzles placed within the tank of the instrument, the aerosol is vaporized. It is ideal for the certification of small and medium-sized areas, when low range of airborne concentration are required. The Rigel RI8303 includes rugged stainless-steel construction, large fill port, individual nozzle control, and a 3″ standard sanitary fitting outlet. An 3” hose adapter (included within the unit) is available for introducing the aerosol into positive pressure systems. RI8303 gives its best in RABS, isolators and safety cabinets.\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable class=\"contenttable\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eType of device\u003c\/td\u003e\n\u003ctd\u003eAerosol generator produced by cold atomized oil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField of use\u003c\/td\u003e\n\u003ctd\u003eHigh efficiency filtering systems integrity tests (ISO 14644-3 – Section 3.2.1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAerosol type\u003c\/td\u003e\n\u003ctd\u003ePolidispersed (cold)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAtomizers\u003c\/td\u003e\n\u003ctd\u003e1 ÷ 6 Laskin nozzles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduced Aerosol\u003c\/td\u003e\n\u003ctd\u003eMax 8000 cfm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAerosol Concentration\u003c\/td\u003e\n\u003ctd\u003eManual regulation:\u003cbr\u003e– 100μg\/l @ 800 cfm\u003cbr\u003e– 10μg\/l @ 8000 cfm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible oil type (*)\u003c\/td\u003e\n\u003ctd\u003eIn accordance with the types indicated in ISO 14644-3 (Section C.6.4): DOP (Dioctyl Phthalate) – PAO (Polyalphaolefin) – DOS (Dioctyl sebacate) – DEHS (di-2-ethylhexyl sebacate) – Shell Ondina EL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOil tank capacity\u003c\/td\u003e\n\u003ctd\u003e5 Litres\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOil level\u003c\/td\u003e\n\u003ctd\u003eCheck window\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eService compressed air\u003c\/td\u003e\n\u003ctd\u003ePressure Max 4 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressed air consumption\u003c\/td\u003e\n\u003ctd\u003eMin. 2.65 cfm\/nozzle @ 1.33 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental conditions during operation\u003c\/td\u003e\n\u003ctd\u003eTemperature 0 °C + 40 °C\u003cbr\u003eRelative Humidity 10 ÷ 90%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage environmental conditions\u003c\/td\u003e\n\u003ctd\u003eTemperature – 20 °C + 55 °C\u003cbr\u003eRelative Humidity 10 ÷ 90% non condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCase\u003c\/td\u003e\n\u003ctd\u003eAluminum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (L x P x H)\u003c\/td\u003e\n\u003ctd\u003e260 x 240 x 280 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e8.5 kg (dry)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"PMT (GB) Ltd.","offers":[{"title":"Default Title","offer_id":43435952767065,"sku":null,"price":0.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1673\/4797\/files\/RI8303_1small.jpg?v=1781523212"},{"product_id":"aerosol-generator-ri8303-copy","title":"Aerosol Generator RI8401","description":"\u003cp\u003e\u003cspan\u003eThe Rigel RI8401 Thermal Aerosol Generator is the perfect choice to test and validate all kinds of areas. This is the smallest and lightest aerosol generator on the market. Plus, having a easy-drainable tank due to a valve located at the bottom makes this unit the most practical unit you can work with. The RI8401 has the ability to start the generation with a remote control (optional). The RI8401 has a great autonomy in continuous duty: at a median concentration it can generate up to 8 hours. No need for special kind of oil to work with this unit: it generates perfectly with the most common fluid such Emery, Ondina, PAO4 and DEHS. This unit starts to generate a consistent amount of aerosol at very low pressures (5 PSI\/0.35 bar), giving the possibility to work even in very small areas. RIGEL RI8401 gives its best in cleanrooms , operating rooms, safety cabinets, isolators and rabs.\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable class=\"contenttable\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eType of device\u003c\/td\u003e\n\u003ctd\u003eAerosol generator produced by condensation of oil thermally vaporised\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField of use\u003c\/td\u003e\n\u003ctd\u003eHEPA filter integrity tests (ISO 14644-3 – Section 3.2.1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem flow rates\u003c\/td\u003e\n\u003ctd\u003e850 m3\/h ÷ 119.000 m3\/h (500 cfm ÷ 70.000 cfm )\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAerosol Concentration (at max oil output capacity)\u003c\/td\u003e\n\u003ctd\u003e10μg\/l @ 70,000 cfm -100μg\/l @ 7,000 cfm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOil output capacity (typical) Oil consumption\u003c\/td\u003e\n\u003ctd\u003eMax 340 mg\/sec @8 bar -Min 13 mg\/sec @0.35 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRun time (Duration)\u003c\/td\u003e\n\u003ctd\u003e974 min @ Min output (Min oil consumption) -38 min @ Max output (Max oil consumption)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible oil type (*)\u003c\/td\u003e\n\u003ctd\u003ePAO (**) – Durasyn 164 – Emery 3004 – Ondina L – Smoke Oil 180 – DEHS – Smoke Oil 135 – Ondina E L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermal chamber temperature\u003c\/td\u003e\n\u003ctd\u003eProgrammable with thermal regulator (max 450 C) (the temperature to be set depends on the type of oil to be used)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOil tank capacity\u003c\/td\u003e\n\u003ctd\u003e1 Liter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressed service gas\u003c\/td\u003e\n\u003ctd\u003eType of gas: Nitrogen, CO2 -Max pressure: 8 bar -Type of coupling: quick coupling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermal chamber temperature\u003c\/td\u003e\n\u003ctd\u003eProgrammable with thermal regulator (the temperature to be set (max 380° C) depends on the type of oil to be used)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePre-heating time\u003c\/td\u003e\n\u003ctd\u003eMin 5 min (\u0026lt; 10 minutes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating cycle (Duty cycle)\u003c\/td\u003e\n\u003ctd\u003eContinuous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTimer module\u003c\/td\u003e\n\u003ctd\u003eto set specific smoke on\/off times or delay the start of smoke operation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical supply\u003c\/td\u003e\n\u003ctd\u003eSelectable 110-120 V 50-60 Hz 10 A 220-240 V 50-60 Hz 5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical protection\u003c\/td\u003e\n\u003ctd\u003eInternal fuse 250V 12.5 A (Appliance must be be earthed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient conditions during operation\u003c\/td\u003e\n\u003ctd\u003eTemperature from 0°C to + 40°C Relative humidity \u0026lt; 95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient storage conditions\u003c\/td\u003e\n\u003ctd\u003eTemperature from 20°C to + 55°C Relative humidity \u0026lt; 95% not condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (L x D x H)\u003c\/td\u003e\n\u003ctd\u003e152 x 320 x 268 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e8.9 kg (empty)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"PMT (GB) Ltd.","offers":[{"title":"Default Title","offer_id":43435956273241,"sku":null,"price":0.0,"currency_code":"GBP","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1673\/4797\/files\/RI8401_1small.jpg?v=1781523626"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1673\/4797\/collections\/R17001_1vsmall.jpg?v=1781521095","url":"https:\/\/pmtgbshop.com\/collections\/hepa-filter-testing\/industry_pharmaceutical.oembed","provider":"PMT (GB) Ltd.","version":"1.0","type":"link"}